-New support for multiple versions of BricsCAD - Users can now switch between BricsCAD v13 and v14 from the VidCAD Main Menu.
-New 64 bit BricsCAD compatibility - BricsCAD users can now use the 64 bit or 32 bit version of v14.
-Resolved issue with Cancel button in the Equipment Settings->Text Placement window. The Cancel button was unresponsive and now works as expected.
-New Autozoom During Cable Transmutate function - This option found in Cable Settings allows a cable to be transmutated even if it is not entirely on the screen.
-New Use Phantom Feather Data option - This setting found in Cable Settings allows cables to feathers created with the Always Feather option to be transmutated without having to select the sysname or I/O name.
-Enhanced I/O in use notification window - The window that appears during Cable Transmutate to inform users that a source is "connected but not to this destination" or a destination is "connected but not to this source" has been enhanced to display the actual connection information. So instead of just saying it is already in use, it says what Sysname it is connected to and what connection point.
-Resolved issue where invalid characters could be entered in the row prefix in the Jack Edit window.
-Resolved issue where the Sysname field on a jack symbol would not always revert to phantom properly which would cause issues when retransmutating the cable.
-Resolved issue that was causing "Use Cable Numbers in Phantom" to not work.
-Resolved issue with original layer states not being restored after Cable Create.
-Resolved issue with Cable Edit that would cause information to display for the nearest real cable if a phantom cable was selected.
-Resolved issue with the Add I/O's to Blocks in Place (AIO) command where some blocks would give a "Could not get list of block I/O's from block" message.
-Resolved issue wth the AIO command that would cause the selected I/O's to reset if the I/O move area was selected.
-Resolved issue with the AIO command where some users would get a fatal error if the block selected had cables connected to the input side of the block.
-Resolved issue with Phantom Equipment Transmutate that was causing VidCAD to create unique block names when it should not have. Which in turn caused trouble transmutating blocks from that point on.
-Resolved issue that was causing a sql error message when an apostrophe was used in the product description area of product specifications. VidCAD now automatically strips out any apostrophe entered.
-Resolved issue in 3D where blocks that are exploded and reblocked that have a model name with lower case characters were creating new models that were unusable. The reblock process now ignores text case of model names.
-Resolved issue where product type was allowing backslash or forward slash which should not be allowed. If users try to enter either character vidcad will strip them out automatically.
-Resolved issue with delete flex where part of the equipment definition was not completely removed from the database causing the item to continue showing up in the equipment list in 3D drawings. Delete flex now completely removes items as expected.
-Resolved issue where an I/O spacing greater than 2 was causing comment text placement to be lower than expected.
-Resolved issue with 2D Racks where models with product type other than "Rack" could not be recalled using Furniture Recall. All 2D racks can now be recalled.
-Resolved issue with sorting by connector column. The column now sorts properly.
-Resolved issue where virtual folder definitions were lost after exporting/adding projects. Virtual folders now travel as expected.
-Resolved issue with the tab order in the Edit Drawing window which was sporadic when the Author field was reached.
-Resolved issue where new Visio drawings could be created with a blank name.
-Resolved issue where the right click menu (on Visio drawings) would display CAD engines instead of just Visio to launch the file.
-Resolved issue with Exports where the reporter would try to save to the C directory even if the project was stored to another drive such as a mapped "V" drive or other local drive letter. The reporter now looks up the entire project path from the SQL database and defaults to that location.
-Resolved issue where padding values were resetting to 2 after reopening report. The padding value for data fields now stores properly.
-Resolved issue where new manufacturer could be created with a blank mfg abbreviation. VidCAD now requires at least one character.
-Resolved spelling error on the command line with the 3D "Corner Clean" command instructions.
-Resolved issue with the Interconnect utility that was not allowing bridged cables to display.
-Resolved issue with the Interconnect utility where inputs were placed one on top of another if the "Used I/O's only" option was selected. Inputs now display properly with the used I/O's only option on.