-Resolved issue that was caused by padding in cable numbers in the RDCable table, leading to missing cable numbers in cables by drawing reports.
-Resolved issue with Dynamic Equipment Edit where the recall function would stop building the equipment list as soon as it encountered a piece of furniture.
-Resolved issue with manufacturer names with less than three characters causing block revision issues if exploded and reblocked in 3D in Phantom Mode.
-Resolved issue with Equipment Delete that was restricting routers from showing up in the query list.
-Resolved issue with Equipment Move in diagram and concept drawings scrambling attributes.
-Resolved issue with library dimentional data not being pulled when defining a new 3D View.
-Resolved issue where new Table or Floor views, in metric drawings, would come in with strange attribute spacing if the size specifications had a height that was larger than the width.
-Resolved issue with Jack Edit where the row name field could not be changed to a number. Jack Edit now allows letters or numbers in row names.
-Resolved issue with missing or scrambled icons in toolbars when switching between different versions of AutoCAD OEM.
-Resolved issue with VidCAD resetting AutoCAD's "NOMUTT" command line variable, which was causing options for commands to be hidden from view.
BricsCAD has resolved a major issue that was affecting VidCAD users that exploded and reblocked equipment in diagram drawings. This fix is available in version v13.2.2 or higher. VidCAD will notify users if they are running an older version and recommend an immediate upgrade.
-Resolved issue in BricsCAD where Phantom Jack Transmutate would cause a fatal error.
-Resolved issue in BricsCAD that would cause cables transmutated to equipment blocks with custom I/O's to have bad data.
-Resolved issue where SQL Server 2005 users could not run Cable Reports, Labels or Exports.
-Resolved issue where Drawing Name would not display for Multicore Cables in Cable Reports, Labels and Exports.
-Resolved issue with the report customization where the ruler would show in centimeters but the filed definitions were still in inches.
-Resolved issue where cables connected to a piece of equipment that was redlined were not updated to show the new source/destination connection information.
-Resolved issue with Blueline where some Bluelined equipment would not display in the Delete/Restore Blueline list.
-Resolved isue with Redline and Blueline that would cause an "Error writing/closing file during Redline/Blueline" to occur even when all other drawings were closed.
-New Edit Facility option. Right click on a facility name and a Reset Last Refresh Log Date utility is listed. This utility will reset the Last Refresh Log date in the database allowing RL to run on all drawings rather that just drawings that have been edited since the last Refresh Log.
-Resolved issue with Cable Delete not removing entries from RDEquip if the cable was connected to a terminal symbol (jack, feather or router).
-Resolved issue with Jack Delete not removing entries from RDCable.
-Resolved issue with Jack Delete not updating entries from RDEquip.
-Resolved issue with Equipment Rename only updating RDEquip for the first piece of equipment selected.
-Resolved issue with the Single Refresh Log (SRL) command that would cause it to remove "Not in Drawing" entries from RDEquip and RDCable.
-Resolved issue where jacks or routers created from within Phantom Cable Transmutate were not being entered in RDEquip as "Not in Drawing" entries.
-Resolved isue where equipment added to a project from Add to List on the VidCAD Main Menu were not placed in the RDEquip table.